Missing single teeth imply a variety of bone sites for implant placement. Incisor regions are frequently impeded by inadequate mesio-distal and/or bucco-lingual bone dimensions, whereas second bicuspid/molar regions are generally affected by inadequate...
Spiral or Cone Beam CT (CBCT) data sets of the patient jaw bones and of the scan template are transcoded by a specific software to produce three-dimensional (3-D) images of the jaw bones and thickness of the mucosa. Software planning...
The scientific literature shows that short implants with a length of ≥ 6 mm are able to support prosthetics in the edentulous mandible. After tooth removal the mandible displays different degrees of atrophy (Fig 1&2). Regarding hard tissue management...
3-D imaging seems the best option unless clinical examination reveals an ample bone volume. The bone quality can be derived from density measurements if CT scan images are available or approximately from the trabecular pattern of 2-D images. Pano....
Teeth extractions are followed by a reduction of the bucco-lingual as well as the vertical dimension of the residual alveolar ridge. The ensuing resorption is progressive and even the basal jaw may become involved. In the lower jaw, the....
At the beginning of the recall control it is necessary to define the intention of a radiograhical control and if it is needed. Radiological controls are only justified in the presence of certain symptoms, anamnesis and/or clinical examination...
At this appointment, a careful evaluation of the patient's oral hygiene and soft tissue response is performed and adjustments made as needed. A daily home-care program must be customized to the individual's ability to clean the...
Inform patient about adequate actions after surgery. Leave around the clock emergency contact numbers in case of urgent complications. Plan or delegate to the referring dentist postoperative recall visits, at day 1 or 2, day 8 - 14 and 4 – 6 weeks...
All tissue surfaces, prosthesis surfaces and implant surfaces should be accessible by oral hygiene aids like toothbrushes, interdental brushes and dental floss or dental tape. It is paramount that, during treatment planning...
The regular recall control appointment, at least every 6 months, should comprise a hygiene check by the dental/oral hygienist or other auxiliary, and include professional cleaning of the restoration, prosthetic components, sulcus and any...
Tomography represents 2-D images of a slice through an object. Computerized tomography (CT) can produce virtual slices and conventional CTs take slice by slice and the machine stops and moves in between slices. Spiral/helical CTs are continuous scans in a...
Radiation source collimated at its source and then diverges into a fan shape to reach detectors. This results in a cone beam.
Pixel (picture + element) is the smallest single component of a 2-D image, whereas a voxel is the smallest element...
When obtaining a panoramic film, one must be aware of the importance of following proper technique and carefully positioning the patient's skull between the X-ray generator and the film. Rotation of the film and radiation source often occurs along a...
Intra-oral radiography can provide sufficiently diagnostic information regarding a dentition and also, in many instances, also yield the necessary pre-surgical planning information for implant surgery. If panoramic radiography is not available...