Presented at EAO 2023, see the clinical performance of gradually anodized implants in a large-scale real-world prospective study. It follows a diverse population with varying comorbidities and demographics highly relevant to routine clinical practice.
Original research from Dr. Ana Ferro and Dr. Miguel Nobre presented at EAO 2023 reports the clinical outcomes of the All-on-4 concept using implants with an ultra-hydrophilic, multi-zone anodized surface and anodized abutments.
Novel anodized abutment and gradually anodized implant surfaces are designed to optimize mucointegration and osseointegration. This scientific poster presented at the EAO Congress Digital Days 2020 shows preliminary data on soft tissue health at interim follow-up, prosthetic...
Extraction of teeth with persistent periapical lesions requires a specific drilling protocol to remove infected bone, to reach healthy trabecular bone and start up a bleeding. Residual dens sclerotic bone may harbor latent pathogenic microorganisms for a...
Missing single teeth imply a variety of bone sites for implant placement. Incisor regions are frequently impeded by inadequate mesio-distal and/or bucco-lingual bone dimensions, whereas second bicuspid/molar regions are generally affected by inadequate...
Conventional dentures are a common treatment option, but, when bone is missing, they may not meet functional, psychological and social needs of the individual. Classical surgical approaches include different...
Oral implants are usually placed in the mandibular and maxillary bone and sometimes in additional bone structures such as the zygomatic, pterygoid or vomer bone. In order to identify relevant anatomical structures, diagnostic evaluation of the anatomy...
Spiral or Cone Beam CT (CBCT) data sets of the patient jaw bones and of the scan template are transcoded by a specific software to produce three-dimensional (3-D) images of the jaw bones and thickness of the mucosa. Software planning...
The majority of commercially available implants are variations of Brånemark’s original design of a screw which he coined as 'fixtures'. This has been the starting point for numerous current market variations that incorporate convergent themes of implant material...
The scientific literature shows that short implants with a length of ≥ 6 mm are able to support prosthetics in the edentulous mandible. After tooth removal the mandible displays different degrees of atrophy (Fig 1&2). Regarding hard tissue management...
3-D imaging seems the best option unless clinical examination reveals an ample bone volume. The bone quality can be derived from density measurements if CT scan images are available or approximately from the trabecular pattern of 2-D images. Pano....
Teeth extractions are followed by a reduction of the bucco-lingual as well as the vertical dimension of the residual alveolar ridge. The ensuing resorption is progressive and even the basal jaw may become involved. In the lower jaw, the....
This is the reversible inflammatory process in the soft tissues around functioning implants. Peri-implant mucositis occurs in almost 60% of subjects (± 30% of sites), restored with implants. Diagnosis is stated by clinical examination: redness, ...